Development of a bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption

  • ORIGINAL ARTICLE
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

We have developed a wavelength division bidirectional transcutaneous optical data transmission system using amplitude shift keying (ASK) modulation. The bidirectional optical data transmission system consists of two kinds of light emitting diodes (LEDs) having different wavelengths and an ASK modulator and demodulator. Two narrow directional visible LEDs with a peak output wavelength of 590 nm were used to transmit data from inside the body to outside the body, and a narrow directional near-infrared LED with a peak output wavelength of 940 nm was used for transmission from outside the body to inside the body. The ASK modulator employs a carrier pulse signal (50 kHz) to support a maximum data transmission rate of 9600 bps. An in vitro experiment showed that the maximum tissue thickness of near-infrared optical data transmission without error was 45 mm; the figure was 20 mm for visible optical data transmission. There was no interference between the signals under full-duplex data transmission. Electric power consumption for the data transmission links was 122 mW for near-infrared light and 162 mW (81 mW × 2) for visible light. From the above results, a bidirectional transcutaneous optical data transmission system promises adequate performance for monitoring and control of an artificial heart.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E Okamoto M Shimanaka S Suzuki K Baba Y Mitamura (1999) ArticleTitleRemote monitoring system of patients with implantable VADs with personal handy-phone system (PHS) Am Soc Intern Artif Organs 45 IssueID3 194–198

    Google Scholar 

  2. E Okamoto E Iwazawa S Suzuki S Fukuoka Y Mitamura (2001) ArticleTitleFeasibility of a remote monitoring system for implantable LVAD patients using PHS telecommucation technology J Artif Organs 4 IssueID3 205–213

    Google Scholar 

  3. E Okamoto Y Mitamura T Mikami (1991) Development of a totally implantable electric assist pump system T Akutsu H Koyanagi (Eds) Artificial heart 3 Springer-Verlag Tokyo 197–203

    Google Scholar 

  4. K Tomoda E Okamoto K Yamamoto Y Mitamura (1994) ArticleTitleDevelopment of a high-performance, totally implantable assist pump system with a built-in optical transmission unit Jpn J Artif Organs 23 IssueID5 1083–1088

    Google Scholar 

  5. A Snyder W Pae J Boehmer G Rosenberg W Weiss W Piece J Thompson J Wewis D Frank H Zintak S Scholl R Korfer A El-Banayosy L Arusoglu O Fey M Morshuis (2001) ArticleTitleFirst clinical trials of a totally implantable destination therapy ventricular assist system J Congest Heart Fail Circ Support 1 IssueID4 185–192

    Google Scholar 

  6. E Tatsumi Y Taenaka K Uesho A Homma T Nishinaka Y Kakuta T Tsukiya N Katagiri K Shioya M Takahashi H Ohnishi K Sato H Takano T Masuzawa M Nakamura K Tsukahara K Tshuchimoto (2001) ArticleTitleLong-term in vivo testing of the National Cardiovascular Center electrohydraulic total artificial heart J Congest Heart Fail Circ Support 1 IssueID4 153–160

    Google Scholar 

  7. T Mussivand PJ Hendry RG Masters WJ Keon (2001) ArticleTitleA totally implantable VAD with remote patient monitoring and control J Congest Heart Fail Circ Support 1 IssueID4 371–377

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eiji Okamoto PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Okamoto, E., Yamamoto, Y., Inoue, Y. et al. Development of a bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption. J Artif Organs 8, 149–153 (2005). https://doi.org/10.1007/s10047-005-0299-7

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-005-0299-7

Key words

Navigation