Abstract
Technological advancements in portable ultrasound units have helped bring high-quality imaging to the bedside of the critically ill patient. The ability to obtain images of a quality that approaches traditional echocardiography imaging systems, including Doppler measurements, has enabled clinicians to obtain dynamic information about cardiac function and cardiopulmonary interaction that was not previously possible. Ultrasound examination, including focused echocardiography, has now become an integral part of care in many critical care units. The availability of transesophageal transducers for portable units has extended the utility of this diagnostic tool in critically ill patients.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Slama M, Maizel J. Echocardiographic measurement of ventricular function. Curr Opin Crit Care. 2006;12(3):241–248.
Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368–1377.
Schiller NB, Shah PM, Crawford M, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989;2(5):358–367.
Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL. Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med. 2007;33(7):1125–1132.
Nagueh SF, Middleton KJ, Kopelen HA, Zoghbi WA, Quinones MA. Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. J Am Coll Cardiol. 1997;30(6):1527–1533.
Ommen SR, Nishimura RA, Appleton CP, et al. Clinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures: A comparative simultaneous Doppler-catheterization study. Circulation. 2000;102(15):1788–1794.
Firstenberg MS, Levine BD, Garcia MJ, et al. Relationship of echocardiographic indices to pulmonary capillary wedge pressures in healthy volunteers. J Am Coll Cardiol. 2000;36(5):1664–1669.
Barbier C, Loubieres Y, Schmit C, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30(9):1740–1746.
Feissel M, Michard F, Faller JP, Teboul JL. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med. 2004;30(9):1834–1837.
Kircher BJ, Himelman RB, Schiller NB. Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol. 1990;66(4):493–496.
Vieillard-Baron A, Chergui K, Rabiller A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med. 2004;30(9):1734–1739.
Vieillard-Baron A, Augarde R, Prin S, Page B, Beauchet A, Jardin F. Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support. Anesthesiology. 2001;95(5):1083–1088.
Charron C, Caille V, Jardin F, Vieillard-Baron A. Echocardiographic measurement of fluid responsiveness. Curr Opin Crit Care. 2006;12(3):249–254.
Ratshin RA, Rackley CE, Russell RO Jr. Determination of left ventricular preload and afterload by quantitative echocardiography in man. Circ Res. 1974;34(5):711–718.
Breitkreutz R, Walcher F, Seeger FH. Focused echocardiographic evaluation in resuscitation management: concept of an advanced life support-conformed algorithm. Crit Care Med. 2007;35(5 suppl):S150–S161.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Glossary
- 2D real-time imaging
-
see B-mode imaging.
- Acoustic impedance
-
a measure of the resistance of tissue to the propagation of ultrasound. It is largely dependent on the density of the tissue and the speed of sound propagation through the tissue.
- Apical window
-
Insonation window located at the apex of the heart, approachable from the transthoracic and transesophageal modalities.
- B-mode imaging
-
two dimensional imaging based on scanning over an area and mapping intensity in two dimensions. By repeating the imaging at a sufficiently fast scan rate, a real-time image can be obtained.
- Color flow Doppler imaging
-
A form of imaging in which Doppler velocity signals are measured over an area, converted to a color map, and overlaid onto the corresponding 2D image.
- Compression waves
-
refers to the longitudinal waves associated with sound traveling through a medium. Longitudinal waves consist of alternating pressure deviations.
- Continuous wave Doppler
-
A form of Doppler interrogation in which a continuous ultrasound is transmitted, with continuous receiving of the reflected waves and calculation of velocity. This mode is sensitive to velocities all along the beam, and thus is useful for finding the maximum velocity only but not where it is located.
- Insonation window
-
A location on the surface of the body or in the esophagus/stomach that is free of interfering structures, allowing acquisition of an image.
- M-mode imaging
-
an imaging mode consisting of a one-dimensional view recorded against time.
- Parasternal window
-
Transthoracic insonation window located to the left of the sternum, about the fourth intercostal space.
- Pulse repetition frequency
-
In pulsed Doppler or B-mode imaging, represents the rate at which the transducer is pulsed. Imaging of deeper structures requires more time for the ultrasound signal to be reflected from the deep structures, requiring a lower PRF, and less information that can be recorded.
- Pulsed wave Doppler
-
A form of Doppler interrogation in which a pulse of ultrasound is transmitted, with the signal received during a specified time window corresponding to a known depth. This mode allows recording of velocities at a particular intracardiac location.
- Reflection
-
A mechanism of ultrasound signal loss that occurs when a wave is reflected away from a tissue interface of differing acoustic impedances.
- Scan area
-
The anatomic area that can be imaged at one time. For linear transducers, the scan area is a square below the transducer. For phased-array sector transducers such as that used in echocardiography, the scan area is pie-shaped, with the narrow angle directly under the transducer.
- Subcostal window
-
Transthoracic insonation window located in the epigastrum below the xyphoid process.
Rights and permissions
Copyright information
© 2010 Springer Science+Business Media, LLC
About this chapter
Cite this chapter
Conrad, S.A. (2010). Focused Echocardiography in the ICU. In: Frankel, H., deBoisblanc, B. (eds) Bedside Procedures for the Intensivist. Springer, New York, NY. https://doi.org/10.1007/978-0-387-79830-1_7
Download citation
DOI: https://doi.org/10.1007/978-0-387-79830-1_7
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-0-387-79829-5
Online ISBN: 978-0-387-79830-1
eBook Packages: MedicineMedicine (R0)