Z Orthop Unfall 2018; 156(02): 200-204
DOI: 10.1055/s-0043-120072
Fallbericht
Georg Thieme Verlag KG Stuttgart · New York

Implantation einer modularen Knietotalendoprothese mit distalem Femurersatz mit kompressiver Osteointegration als Rückzugsoption bei komplexer femoraler posttraumatischer Ausgangssituation

Implantation of a Modular Distal Femoral Replacement with Compressive Osseointegration as a Salvage Procedure in a Complex Femoral Posttraumatic Setting
Anna Janine Schreiner
1   Klinik für Unfall- und Wiederherstellungschirurgie, BG Klinik Tübingen
,
Peter Marten de Zwart
1   Klinik für Unfall- und Wiederherstellungschirurgie, BG Klinik Tübingen
,
Christian Arnscheidt
1   Klinik für Unfall- und Wiederherstellungschirurgie, BG Klinik Tübingen
,
Ulrich Stöckle
1   Klinik für Unfall- und Wiederherstellungschirurgie, BG Klinik Tübingen
,
Björn Gunnar Ochs
2   Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Freiburg
› Author Affiliations
Further Information

Publication History

Publication Date:
22 November 2017 (online)

Zusammenfassung

Hintergrund Größere Knochendefekte und -verluste sind sowohl in der Tumorchirurgie als auch in der komplexen Primär- und Revisionsendoprothetik des Kniegelenks für die Rekonstruktion ausschlaggebend. Die gängige Option der zementierten wie auch zementfreien Implantation langstieliger Implantate gerät bei großen Knochendefekten oft an ihre Grenzen und ist des Weiteren aufgrund des relativ hohen Risikos der aseptischen Lockerung im Verlauf gefährdet. Eine allgemein gültige Festlegung auf die optimale Implantatfixierung im Bereich des distalen Femurs ist bisher noch nicht erfolgt. Eine weitere Verankerungsoption ist die Nutzung der auf dem Wolffʼschen Transformationsgesetz beruhenden zementfreien, kompressiven Osteointegration. Diese Methode wurde entwickelt, um die hohen aseptischen Lockerungsraten in der Revisionsendoprothetik zu senken und gleichzeitig bei großen Knochendefekten eingesetzt zu werden. Das sog. Compress®-System bzw. CPS ermöglicht eine solche distale Femurrekonstruktion. Das bisherige Haupteinsatzgebiet ist die Tumorendoprothetik. Für den Einsatz in der komplexen posttraumatischen Situation oder Revisionsendoprothetik liegen kaum Studiendaten vor.

Patienten Es werden 2 Fallberichte zweier männlicher Patienten (59 und 56 Jahre) mit 1-Jahres-Ergebnissen präsentiert. In beiden Fällen bestand der Zustand nach Polytrauma mit komplexer posttraumatischer Ausgangssituation am distalen Femur (Deformität, Knochendefekte, Voroperationen) und gleichseitig einliegender Hüftendoprothese. Es erfolgte die Implantation einer modularen KTP, bestehend aus einer zementierten modularen Tibiabasisplatte sowie einem distalen Femurersatz, mit zementfreier Implantatverankerung mittels kompressiver Osteointegration. Die beiden Fälle wurden prospektiv klinisch und radiologisch dokumentiert.

Ergebnisse Es zeigten sich gute klinisch-radiologische Ergebnisse nach distalem Femurersatz mittels kompressiver Osteointegration. Es waren keine Folge- oder Revisionseingriffe erforderlich. Die Patienten konnten ihre berufliche Tätigkeit in der Nachbeobachtungsphase wieder aufnehmen. Die Literatur zeigt vergleichbare Überlebensraten für das CPS im Vergleich zu den konventionellen Verfahren. Langzeitergebnisse und größere Daten für die Revisionsendoprothetik bzw. posttraumatische Fälle fehlen bisher.

Schlussfolgerung Neben der Anwendung in der Tumorendoprothetik kann auch die komplexe femorale Ausgangssituation mit großen Knochendefekten als Indikation für den distalen Femurersatz mittels Compress-System für den klinischen Alltag evaluiert werden. Gerade wenn gleichseitig eine HTP einliegt, kann diese Option interprothetische Stress-Riser vermeiden.

Abstract

Background Large bone defects and losses play a crucial role in both tumour surgery and in complex primary and revision total knee replacement. The established options of cemented or uncemented long intramedullary stems are limited by large bone defects and are at risk from relatively high exposure to aseptic loosening. There is no general valid agreement on implant fixation of the distal femur. A further option is the cementless fixation method with compressive osseointegration, based on the so-called Wolff law of bone remodelling. This method was developed in order to reduce the high loosening rates in revision arthroplasty due to intense stress shielding and is intended to be applied in patients with huge bone losses. The so-called Compress® system (or CPS) allows such a distal femur reconstruction. It has mainly been applied and evaluated in tumor endoprosthetics. There are currently few data on the application of this system in complex distal femoral posttraumatic deformity or revision arthroplasty.

Patients A case report of two male patients aged 59/56 years with a 1-year follow-up is presented. Both patients had a complex post-traumatic femoral deformity with bone loss, prior surgery and an ipsilateral hip replacement. Implantation was performed of a modular total knee replacement, consisting of a cemented modular tibia base plate and distal femoral replacement with cementless implant fixation by compressive osseointegration. Both patients were clinically and radiologically evaluated prospectively.

Results Good clinical and radiological results were demonstrated in both patients after distal femoral replacement by compressive osseointegration. There was no need for further or revision surgery. Both patients were rapidly able to resume their jobs. The survival rates for CPS were comparable to published values with conventional procedures. There are yet no long-term results or extensive data for revision arthroplasty or posttraumatic cases.

Conclusions Besides distal femoral replacement with compressive osseointegration in oncological arthroplasty, the indication of complex distal femoral settings with large bone defects can be evaluated for daily clinical routine. Especially if there is ipsilateral total hip replacement, this option might be used to avoid interprosthetic stress risers.

 
  • Literatur

  • 1 Wolf JH. [Julius Wolff and his “law of bone remodeling”]. Orthopade 1995; 24: 378-386
  • 2 Avedian RS, Goldsby RE, Kramer MJ. et al. Effect of chemotherapy on initial compressive osseointegration of tumor endoprostheses. Clin Orthop Relat Res 2007; 459: 48-53
  • 3 Goldman LH, Morse LJ, OʼDonnell RJ. et al. How often does spindle failure occur in compressive osseointegration endoprostheses for oncologic reconstruction?. Clin Orthop Relat Res 2016; 474: 1714-1723
  • 4 Zimel MN, Farfalli GL, Zindman AM. et al. Revision distal femoral arthroplasty with the Compress® prosthesis has a low rate of mechanical failure at 10 years. Clin Orthop Relat Res 2016; 474: 528-536
  • 5 Monument MJ, Bernthal NM, Bowles AJ. et al. What are the 5-year survivorship outcomes of compressive endoprosthetic osseointegration fixation of the femur?. Clin Orthop Relat Res 2015; 473: 883-890
  • 6 Calvert GT, Cummings JE, Bowles AJ. et al. A dual-center review of compressive osseointegration for fixation of massive endoprosthetics: 2- to 9-year followup. Clin Orthop Relat Res 2014; 472: 822-829
  • 7 Kagan R, Adams J, Schulman C. et al. What factors are associated with failure of compressive osseointegration fixation?. Clin Orthop Relat Res 2016; 475: 698-704
  • 8 Tyler WK, Healey JH, Morris CD. et al. Compress periprosthetic fractures: interface stability and ease of revision. Clin Orthop Relat Res 2009; 467: 2800-2806
  • 9 Henderson ER, Groundland JS, Pala E. et al. Failure mode classification for tumor endoprostheses: retrospective review of five institutions and a literature review. J Bone Joint Surg Am 2011; 93: 418-429
  • 10 Healey JH, Morris CD, Athanasian EA. et al. Compress knee arthroplasty has 80 % 10-year survivorship and novel forms of bone failure. Clin Orthop Relat Res 2013; 471: 774-783