Home > Journals > The Journal of Sports Medicine and Physical Fitness > Past Issues > The Journal of Sports Medicine and Physical Fitness 2019 February;59(2) > The Journal of Sports Medicine and Physical Fitness 2019 February;59(2):253-8

CURRENT ISSUE
 

JOURNAL TOOLS

Publishing options
eTOC
To subscribe
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as
Share

 

ORIGINAL ARTICLE  EXERCISE PHYSIOLOGY AND BIOMECHANICS 

The Journal of Sports Medicine and Physical Fitness 2019 February;59(2):253-8

DOI: 10.23736/S0022-4707.18.08195-1

Copyright © 2018 EDIZIONI MINERVA MEDICA

language: English

The validity and reliability of the My Jump 2 app for measuring the reactive strength index and drop jump performance

Tom HAYNES 1, Chris BISHOP 2, Mark ANTROBUS 3, Jon BRAZIER 1

1 Center of Applied Science, City and Islington College, London, UK; 2 London Sport Institute, Middlesex University, London, UK; 3 Sport, Exercise and Life Sciences, University of Northampton, Northampton, UK



BACKGROUND: This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app’s ability to measure the reactive strength index (RSI).
METHODS: Fourteen male sport science students (age: 29.5±9.9 years) performed three drop jumps from 20 cm and 40 cm (totaling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach’s alpha (α), coefficient of variation (CV) and Bland-Altman plots.
RESULTS: Near perfect agreement was seen between devices at 20 cm for RSI (ICC=0.95) and contact time (ICC=0.99) and at 40 cm for RSI (ICC=0.98), jump height (ICC=0.96) and contact time (ICC=0.92); with very strong agreement seen at 20 cm for jump height (ICC=0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r=0.94; 40 cm; r=0.97), jump height (20 cm: r=0.80; 40 cm; r=0.96) and contact time (20 cm=0.96; 40 cm; r=0.98).
CONCLUSIONS: The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.


KEY WORDS: Physical fitness - Exercise test - Mobile applications

top of page