Skip to main content

A systematic review on the rotational thrombelastometry (ROTEM®) values for the diagnosis of coagulopathy, prediction and guidance of blood transfusion and prediction of mortality in trauma patients

Abstract

Introduction

Viscoelastic assays have been promoted as an improvement over traditional coagulation tests in the management of trauma patients. Rotational thromboelastometry (ROTEM®) has been used to diagnose coagulopathy and guide hemostatic therapy in trauma. This systematic review of clinical studies in trauma investigates the ROTEM® parameters thresholds used for the diagnosing coagulopathy, predicting and guiding transfusion and predicting mortality.

Methods

Systematic literature search was performed using MEDLINE, EMBASE and Cochrane databases. We included studies without restricting year of publication, language or geographic location. Original studies reporting the thresholds of ROTEM® parameters in the diagnosis or management of coagulopathy in trauma patients were included. Data on patient demographics, measures of coagulopathy, transfusion and mortality were extracted. We reported our findings according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Quality assessment and risk of bias were performed using Newcastle Ottawa Scale (NOS) and the quality assessment of diagnostic accuracy studies (QUADAS-2) tools, respectively.

Results

A total of 13 observational studies involving 2835 adult trauma patients met the inclusion criteria. Nine studies were prospective and four were retrospective. There were no randomized controlled trials. The quality of the included studies was moderate (mean NOS 5.92, standard deviation 0.26). Using QUADAS-2, only 1 study (7.6 %) had low risk of bias in all domains, and 9 studies (69.2 %) had low risk of applicability concerns. Outcomes from 13 studies were grouped into three categories: diagnosis of coagulopathy (n = 10), prediction of massive transfusion or transfusion guidance (n = 6) and prediction of mortality (n = 6). Overall, specific ROTEM® parameters measured (clot amplitude and lysis) in the extrinsically activated test (EXTEM) and the fibrin-based extrinsically activated test (FIBTEM) were consistently associated with the diagnosis of coagulopathy, increased risk of bleeding and massive transfusion, and prediction of mortality. Presence of hyperfibrinolysis by ROTEM® was associated with increased mortality.

Conclusions

Most of the evidence indicates that abnormal EXTEM and FIBTEM clot amplitude (CA5, CA10) or maximal clot firmness (MCF) diagnose coagulopathy, and predict blood transfusion and mortality. The presence of fibrinolysis (abnormal lysis index [LI30] or maximum lysis [ML]) was also associated with mortality. ROTEM® thus, may be of value in the early management of trauma patients.

Background

The degree of injury and hypoperfusion are implicated as initiators of the acute coagulopathy of trauma/shock (ACoTS) that occurs immediately after injury [1, 2]. ACoTS occurs in approximately 25 % of all severely injured patients and is associated with a three-fold increase in mortality [1]. Patients with ACoTS have complex coagulation defects, higher transfusion requirements, organ dysfunction, longer hospital stays and poorer outcomes including higher mortality rates [1, 35].

Current standards for the management of ACoTS are based mainly on results of standard coagulation tests (SCTs) [69] such as prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), platelet count (PLT), and fibrinogen level [10]. Currently, many trauma centers use INR >1.5 and PLT <100 × 109 L−1 to establish the presence of coagulopathy [11]. These values are widely used and incorporated into existing guidelines, despite lacking robust evidence support. [9, 1113] Standard coagulation tests have long turnaround times (TAT), require transportation of the sample to the laboratory, separation of plasma from the red cells and detect only the initial phases of clot formation [7]. These tests were originally developed to diagnose coagulation abnormalities in congenital bleeding disorders and to monitor anticoagulation therapy, and their role in guiding transfusion therapy in trauma have not been validated [7]. Patients with ACoTS would benefit from a test that could quickly identify coagulation abnormalities, permit transfusion guidance, reduce exposure to allogeneic blood products and improve clinical outcomes by guiding rapid correction of any hemostatic defect. Thromboelastography (TEG®) and rotational thromboelastometry (ROTEM®) have been used in cardiovascular surgery and liver transplantation; [1417] and, more recently, have been applied to trauma. The use of these devices may reduce hemorrhage as reported in a recent Cochrane systematic review [18] in patients requiring massive transfusion.

ROTEM® has recently been used as point-of-care (POC) test to optimize haemostatic resuscitation in trauma patients [19]. It utilizes a small volume of whole blood to assess hemostatic function from initiation of clot formation, clot propagation and clot lysis [20]. Additionally, ROTEM® provides information on platelet number/function and fibrinogen reserve. Luddington, in a review on ROTEM® assays and parameters, offers additional methodologic details about the test. [19] There are four assays which are run simultaneously: extrinsically activated test using tissue factor as activator (EXTEM) which detects defects associated with extrinsic pathway; intrinsically activated test using ellagic acid (INTEM) which detects defects of the intrinsic pathway; fibrinogen test (FIBTEM) using cytochalasin-D as platelet inhibitor which detects the contribution of fibrinogen to the clot; and a test using aprotinin inhibitor (APTEM), a test for hyperfibrinolysis (HF). In other clinical settings such as in liver transplantation, cardiac and vascular surgery, the use of ROTEM® has been linked to a reduction of exposure to allogeneic blood products and improvement of outcomes [16, 2123]. In trauma, recent investigations suggest that ROTEM® can be used in the diagnosis of coagulopathy, prediction and guidance of transfusion and reduction of unnecessary exposure to allogeneic blood products [2430]. Results of ROTEM® parameters are used for treatment decisions; however the reported thresholds used to diagnose coagulopathy and to guide transfusion vary substantially among reports.

There is a need for determining ROTEM® parameters and their thresholds that establish the presence of coagulopathy, predict bleeding, guide the hemostatic resuscitation and predict mortality. We conducted a systematic review of literature to summarize the reported ROTEM® parameters and their thresholds for this purpose. The primary goal was to determine evidenced based thresholds that could be incorporated into ROTEM® algorithms in the trauma resuscitation protocols.

Methods

This descriptive systematic review was reported in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [31].

Information sources and search technique

Two reviewers (PVV and LTDL) performed a systematic review of the indexed literature on ROTEM® studies that reported thresholds of ROTEM® parameters in trauma patients. The highly sensitive search strategy was developed by the review team in consultation with the health information specialist (Additional file 1). We searched MEDLINE, EMBASE and EBM Reviews (Cochrane Database of Systematic Reviews) from 1946 to March 2016 without restricting language or geographic location. The reviewers checked titles, abstracts, full texts, and personally contacted the authors (or manufacturer’s representative) to retrieve or clarify required information.

Eligibility criteria and study selection

We searched for observational studies and randomized controlled trials (RCTs) in trauma where cut off values of ROTEM® parameters were reported in: (1) diagnosing coagulopathy; (2) predicting or guiding transfusion; and, (3) predicting mortality. We excluded animal studies, studies assessing patients with thermal injuries, case reports, case series involving <10 patients, and abstracts from conferences. Outcomes included accuracy in diagnosing coagulopathy, predicting massive transfusion, diminishing exposure to allogeneic blood products and predicting mortality. The reviewers independently screened titles and abstracts of all articles in a hierarchical manner by following the PRISMA guidelines [31, 32]. Titles were categorized as “include”, “exclude” or “undetermined” using an excel spreadsheet. The articles classified as “include” and “undetermined” by either reviewer were included for full text evaluation at the next level. Any discrepancies concerning agreement at both levels were resolved by discussion, consensus or consultation with a third reviewer (SR). Inter-rater agreement for inclusion was assessed using Cohen’s Kappa [33].

Data abstraction and analysis

The reviewers independently collected data using standardized forms developed in collaboration with the study team. Reviewers were not blinded to the author or publication source of studies. The following data were collected: author, year, country, design, control group, patient population, duration of study, sample size, study objective, patient characteristics, and outcomes (coagulopathy, exposure to allogeneic blood products, and mortality). We also retrieved information regarding ROTEM® parameters, data on accuracy (sensitivity and specificity) of SCTs thresholds and ROTEM® thresholds used to diagnose coagulopathy, guide transfusion, predict exposure to allogeneic blood products, and predict mortality. The methodological quality of the studies was assessed using the Newcastle-Ottawa Scale [34] and Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2) [35] by both reviewers (PVV, LTDL).

Results

The search strategy identified a total of 1220 citations through MEDLINE, Cochrane and EMBASE data bases. We excluded 1179 citations as they were either unrelated to our question or were duplicates. Forty one citations were deemed relevant and were reviewed at full text level. Thirteen studies enrolling a total of 2835 patients met the eligibility criteria and were included (Fig. 1) [2528, 30, 3643]. We searched the references within each included study, and no additional studies were identified. The Kappa statistics for inter-rater agreement for titles plus abstracts, and full manuscript screening was 0.84 and 0.76, respectively.

Fig. 1
figure 1

Flow Diagram of included and excluded studies

Study characteristics

Ten studies (Table 1) were conducted in Europe [2628, 3642]; two in Afghanistan, conducted by United Kingdom (UK) military researchers [25, 30] and one study included sites in both Europe and the UK [43]. All 13 studies were conducted in adult patients, included blunt and penetrating injuries, in the civilian [2628, 3643] or in the military settings [25, 30]. A single study included patients above 13 years of age [41] and no study was conducted exclusively in pediatric trauma patients. All but two [42, 43] studies were single centered [2628, 3641]. The sample sizes varied from 25 [25] to 808 [43] (median sample size 88, interquartile range 53–323). The median age of patients included in the studies ranged from 21 (IQR 18–35) [25] to 47 (IQR 26–66) [39] years. The percent of male patients ranged from 67 % [37] to 100 % [30]. All studies provided information on injury severity score (ISS), and the median ISS ranged from 12 (IQR 4–25) [41] to 75 (IQR 75–75) [37].

Table 1 Summary of studies included in the review

Methodological quality

There were no randomized controlled trials identified. Nine cohort studies were prospective [25, 26, 30, 36, 37, 4043] and 4 were retrospective [27, 28, 38, 39]. The studies had moderate methodological quality as determined by the Newcastle Ottawa scale (NOS) (Table 2) with a mean score of 5.92 (SD = 0.26), with a possible range of 1 to 9. Ten studies enrolled consecutive patients [2628, 3642]. All studies had no comparable control group as defined in the NOS scale. Two studies used healthy volunteers as controls [30, 36] and one study used hospitalized polytrauma patients, and compared to patients with isolated brain injury [40]. All studies were assessed for quality of diagnostic accuracy using QUADAS-2 tool [35] (Table 3, Fig. 2a-b). Considering the domains of patient selection, index test, reference standard, flow and timing, only 1 study (7.6 %) had low risk of bias in all domains [40]; 7 studies (53.8 %) had low and unclear risks [26, 28, 30, 38, 39, 41, 42]; and 5 studies (38.4 %) had high risk of bias in at least 1 domain [25, 27, 36, 37, 43]. In terms of applicability concerns, 9 studies (69.2 %) [2628, 30, 38, 39, 4143] had low concerns and 4 studies (30.7 %) [25, 36, 37, 40] had at least 1 domain with high concern.

Table 2 The Newcastle Ottawa scale for the cohort studies included in the review
Table 3 QUADAS-2 Tool: summary of assessment of risk of bias and applicability concerns
Fig. 2
figure 2

a Proportion of studies with low, high or unclear risks of bias. b Proportion of studies with low, high or unclear applicability concerns

Outcomes

We found ten studies addressing ROTEM® thresholds for diagnosis of coagulopathy [25, 26, 30, 36, 37, 3943], 6 studies addressing thresholds for prediction or guidance of transfusion [27, 28, 38, 40, 41, 43], and 6 studies addressing prediction of mortality [26, 27, 37, 39, 40, 42]. Two studies used 4 ROTEM® assays (EXTEM, INTEM, FIBTEM and APTEM) [23, 33]; 4 studies used 3 assays (EXTEM, INTEM, and FIBTEM) [25, 28, 36, 39]; 4 studies used 2 assays (EXTEM and FIBTEM) [27, 40, 42, 43]; 1 study used 2 other assays (EXTEM and INTEM) [38] and 2 studies used 1 assay (EXTEM) [30, 41].

Studies addressing thresholds of ROTEM® parameters to diagnose ACoTS

Definition of coagulopathy by SCTs and ROTEM® parameters varied across all studies. Five studies [25, 36, 39, 41, 43] used different SCTs as gold standards, with different cut off values to define coagulopathy. For example, one study used INR >1.6 and/or aPTT >60s and/or a platelet count <100 × 109 L−1 and/or fibrinogen < 1 g/L [36]. In contrast, another study used a prothrombin time index (PTI) test <70 % (a value of <70 % in PTI is equivalent to INR >1.3), aPTT >35 s, and fibrinogen <1.50 g/L [39]. Lastly, coagulopathy was defined by Davenport and Hagemo as an INR >1.2 [41, 43].

In ROTEM®, 10 studies reported thresholds of parameters in detecting the various defects in ACoTS [25, 26, 30, 36, 37, 3943] (Table 4). However, there was a wide variation on the parameters chosen, and their cut off values. Better designed studies used SCTs as controls when determining thresholds and cut-off values. Other studies used the recommendations from previous consensus meetings [44]. Finally, in other studies, authors used previous institutional experience, or cut-off values pre-established by the ROTEM® manufacturer. Studies that used SCTs as reference standards for comparisons are described here. Table 4 describes all evidence in details.

Table 4 Studies addressing ROTEM® thresholds used for diagnosis of trauma coagulopathies

ROTEM® thresholds determined with comparison to standard controls (SCTs)

In a study conducted by Rugeri [36], thresholds were determined by evaluating the extent of correlation between ROTEM® parameters with corresponding SCTs (CA15-EXTEM with PT: r = 0.66, p < 0.0001); clot formation time [CFT]-INTEM with aPTT: r = 0.91, p < 0.0001; CA10-FIBTEM with fibrinogen level: r = 0.85, p < 0.0001; CA15-INTEM with PLT count: r = 0.57, p < 0.0001). The group found cut-off values of EXTEM CA15 < 32 mm and FIBTEM CA10 < 5 mm to detect laboratory PT > 1.5 and fibrinogen level <1 g/L, with high sensitivity (87 % and 91 %) and specificity (100 and 85 %), respectively. In another study, Levrat determined the cut off values by assessing correlation between ROTEM® parameters and euglobin lysis time (ELT), used as the gold standard control [37]. In this study, a threshold of 18 mm (MCF-EXTEM), 71 % (CLI30) AND 7 % increase of MCF-APTEM, sensitivity was, 100, 75 and 80 %, respectively with a specificity of 100 %. Moreover, Davenport [41] and Rourke [42] used ROTEM® CA5 < 35 mm as threshold based on correlation with normal PT values to discriminate normal from the abnormal curves in patients with ACoTS. Hagemo used ROTEM® threshold value of EXTEM CA5 ≤ 37 mm and FIBTEM A5 ≤ 8 mm to detect ACoTS [43]. These authors used INR > 1.2 and fibrinogen concentration of ≤1.61 g/L to define ACoTS, respectively [43]. A feasibility study [25] in a deployed military trauma setting demonstrated that an abnormal CA10 was associated with a subsequent development of an abnormal MCF (<45 mm). MCF <45 mm was present in a 100 % of MT patients. When PT > 18 s and aPTT >60s were used as the gold standard for ACoTS, only 10.5 % of patients were defined as coagulopathic. By comparing these results with ROTEM® results, it was found that 64 % were coagulopathic (FIBTEM-MCF < 45 mm), (p = 0.0005). Another study [41] reported that the threshold EXTEM CA5 ≤ 35 mm predicted INR > 1.2 in 77 % of cases. In TBI patients, Schochl [39] reported a cut off value of EXTEM-CT > 80s, compared to PTI < 70 %, to define coagulopathy (p = 0.003). Finally, in another study in the military setting [30] the authors compared PT > 18 s (gold standard) to diagnose coagulopathy and identified that early CA5 < 32 mm and CA10 < 40 mm predicted the hypocoagulation state with a sensitivity/specificity of CA5 96/58 % and CA10 100/70 %, respectively, compared to SCTs.

Hypofibrinogenemia

Two studies investigated the use of FIBTEM CA10 < 5 mm and FIBTEM CA5 < 10 mm for diagnosing different degrees of hypofibrinogenemia. In the first study [36], FIBTEM CA10 < 5 mm diagnosed fibrinogen levels below 1.0 g/L with sensitivity of 87 % and specificity of 91 %. The second study [42] reported EXTEM CA5 < 36 mm with a sensitivity of 53 % and specificity of 87 % for discerning patients with fibrinogen levels <1.5 g/L. For FIBTEM CA5 < 10 mm, the reported sensitivity and specificity were 78 and 70 % respectively for predicting a fibrinogen level below 1.5 g/L.

Hyperfibrinolysis

Three studies [26, 37, 40] reported thresholds of different ROTEM® parameters to diagnose degrees of hyperfibrinolysis (HF) such as mild, moderate and fulminant. Two studies [26, 37] compared their findings with SCTs. The first study [37] defined HF as euglobulin lysis time (ELT) <90 min (used as gold standard) in a series of 23 patients. The authors used EXTEM MCF ≤ 18 mm, clot lysis index at 30 min (CLI30) < 71 % and APTEM MCF 7 % increase to define hyperfibrinolysis (HF) (sensitivity 100, 75, 80 % and specificity 100 % for all, respectively) in these patients with an abnormal ELT test. The second study [26] enrolled 33 trauma patients diagnosed with HF by ROTEM®. They used clot lysis in EXTEM and INTEM assays at different time points across the ROTEM® tracing to define the three patterns of HF, confirmed by the APTEM test. A complete clot lysis (ML = 100 %) within 30 min was used to define patients with fulminant HF; complete clot lysis between 30 and 60 min defined intermediate HF and complete clot lysis after 1 h to define late HF. The median values of laboratory fibrinogen was lower in fulminant HF group and intermediate HF group when compared with late HF group (fulminant HF: 0.5 g/L; intermediate HF: 0.49 g/L compared with late HF 1.04 g/L, p = 0.048 for both).

Platelet count

A single study [36] evaluated the correlation between platelet count and INTEM CA15 (r = 0.57, p < 0.0001). However, the threshold value of INTEM CA15 = 46 mm showed poor positive predictive (PPV) values in the diagnosis of laboratory platelet count below 50 × 10−9L−1 (sensitivity: 100 % [95 % CI 71–100], specificity 83 % [95 % CI 82–83]; PPV 17 % [95 % CI 12–17], negative predictive value [NPV] 100 % [95 % CI 98–100]; AUC 0.92).

Studies addressing thresholds of ROTEM® parameters in predicting or guiding transfusion

Predicting transfusion

Six studies reported ROTEM® thresholds either in predicting transfusion [28, 38, 40, 41, 43], including MT [28, 38, 41, 43], or guiding transfusion [27] (Table 5). Massive transfusion was defined by the need for transfusion of ≥10U of RBCs within the first 12 h [41] or 24 h [28, 38] of hospital admission in three studies. Values outside the reference range for EXTEM and INTEM CT, CFT, CA at 10, 20 and 30 min, as well as reduced MCF were more likely in patients who required a MT vs. patients who did not (p < 0.0001, for all) [28, 38]. The reference ranges used in this study were the same established by the same group, in a previous study that used SCTs as control [26].

Table 5 Studies addressing ROTEM® thresholds used to predict or guide blood transfusion

Davenport [41] demonstrated that EXTEM CA5 ≤ 35 mm predicted the need for MT with higher detection rate compared to INR > 1.2 (71 vs. 43 %, p < 0.001). Schochl [28], using threshold pre-established in a previous study by the same group [26] reported that both FIBTEM A10 ≤ 4 mm (ROC AUC = 0.83) and FIBTEM MCF ≤ 7 mm (ROC AUC = 0.84) were predictive of the need for MT. Lastly, Hagemo [43] demonstrated that threshold values of EXTEM CA5 ≤ 40 mm predicted MT in 72.7 % and FIBTEM CA5 ≤ 9 mm predicted MT in 77.5 %, respectively. However detection rate for MT was found to be highest for INR, as compared to EXTEM CA5 (51.1 and 45.5 %, respectively). The optimum threshold value for fibrinogen in predicting MT was ≤1.90 g/L with a detection rate of 77.8 % and a positive predictive value of 14.

Guiding transfusion

Schochl [27], in a retrospective analysis of trauma patients who received ≥5U RBCs within 24 h, and whose coagulation management was guided by ROTEM®, developed a clinical practice guideline using thresholds of ROTEM® parameters to guide transfusion. The group used a threshold of FIBTEM MCF < 10 mm to guide transfusion of fibrinogen concentrate (FC) and used EXTEM CT > 1.5 times normal to guide PCC administration. Reference ranges used for these ROTEM® tests’ parameters were previously determined in a multi-center investigation by Lang [45]. The authors were able to demonstrate a reduction in the number of RBC units transfused. The use of RBC units was avoided in 29 % of patients receiving FC and PCC therapy compared to only 3 % avoided in the group receiving fresh frozen plasma (FFP) (p < 0.001).

Studies addressing thresholds of ROTEM® parameters in predicting mortality

Six studies evaluated ROTEM® thresholds in predicting mortality (Table 6) [26, 27, 37, 39, 40, 42]. These studies evaluated mortality at different time points, including: within 24 h of arrival [40]; death in hospital [26, 40]; death within 24 h and 28 days [42], 30 days [40], and two studies did not define the time to death [27, 37]. Two studies reported that trauma patients with the diagnosis of HF had higher rates of mortality [26, 37]. The studies defined HF differently: Schochl defined HF as a complete clot lysis (ML = 100 %) on ROTEM® at different time intervals as fulminant HF, intermediate HF and late HF as described above [26]. Finally, Levrat defined HF as an ELT < 90 min. [37] We describe here under the studies that adjusted their findings for confounders, or compared findings with previously validated trauma scores [46, 47]. The full description of the evidence is on Table 6.

Table 6 Studies addressing ROTEM®® thresholds for the prediction/reduction of mortality

Tauber [40] found a significant increase in mortality with FIBTEM < 7 mm (21 vs. 9 %, p = 0.006) and EXTEM MCF < 45 mm (25.4 vs 9.4 %, p < 0.001). Similarly, EXTEM MCF was independently and negatively associated with early mortality (OR 0.94, 95 % CI 0.9–0.99). The author additionally reported 85.7 % mortality in patients with fulminant HF (ML100% within 30 min), and 11.1 % mortality in patients with moderate HF (ML100% between 30 and 60 min). Rourke [42] reported that a low FIBTEM A5 < 9.5 mm was an independent predictor of 24 h and 28 days mortality (p < 0.001).

In a study in brain injury patients, Schochl [39] demonstrated an independent association between FIBTEM MCF < 9 mm (ROC: 0.77; 95 % CI, 0.665–0.850, p < 0.001) and aPTT > 35 s (ROC 0.79; 95 % CI 0.686–0.868, p < 0.001), and mortality. Moreover, in this study, ROTEM® revealed shorter CT in EXTEM and INTEM (p < 0.001), shorter CFT in EXTEM and INTEM (p < 0.0001), and higher MCF in EXTEM and INTEM (p < 0.01) in survivors compared with non-survivors. Finally, in another study conducted the Schochl [27], where trauma patient resuscitation was guided by ROTEM® with FC and PCC, a reduction in the observed mortality than the predicted mortality by TRISS and RSS was demonstrated (24.4 vs. 33.7 %, p = 0.032).

Discussion

Main findings

We performed a systematic review of the literature to ascertain the existing evidence on the reported thresholds of ROTEM® parameters in diagnosing coagulopathy, predicting or guiding transfusion and predicting mortality in trauma patients. Thirteen studies evaluating 2835 patients met our inclusion criteria. Overall, the methodological quality of the included studies was moderate. In general, the patient populations were different across studies. We found studies using different ROTEM® parameters and different thresholds for the same ROTEM® parameter for the diagnosis of coagulopathy and guidance of component transfusions. We did not find any randomized controlled trials, and the majority of the retrospective or prospective cohort studies found in the review did not have a gold standard coagulation test used for comparison. Where SCTs results were used as the gold standard, there were no studies done to validate the chosen cut-off. We were not able to pool the data and conduct meta-analysis due to the marked clinical heterogeneity among the studies. Considering the limited number of studies and the moderate methodological quality, we concluded that there is still no robust evidence supporting the thresholds of ROTEM® parameters reported in the literature in diagnosing coagulopathy, guiding or predicting transfusion, and predicting mortality.

For diagnosis of coagulopathy, the most properly designed studies, using a control (SCTs), identified several different parameters and thresholds. However, definition of coagulopathy by SCTs was not standardized. Most common parameters used to define coagulopathy across the studies were EXTEM-CA5, CA10, CA15, which were correlated with PT and INR. The cut-off values varied from 5 mm in CA5 to 35 mm in CA15. Of note, several other studies used arbitrary values obtained from previous expert group meetings, previous author’s experience or from reference values from the manufacturer.

Hypofibrinogenemia was diagnosed, in general, with FIBTEM CA5 and CA10 (<10 mm and <5 mm, respectively). Gold standards SCTs used for comparison were fibrinogen <1.0 g/L or 1.5 g/L. In the assessment of hyperfibrinolysis, complete clot lysis (ML100 %) and LI60 < 85 % were used as definition of hyperfibrinolysis, with the ELT < 90 min as the gold standard for comparison.

For prediction of transfusion, the best designed study established EXTEM-CA5 ≤ 35 mm using INR as control. The other studies did not use SCTs as gold standards for control. In those studies, the parameters and their cut off values were established from previous author’s experiences or from the manufacturer of the ROTEM® device. Values outside the reference range for EXTEM and INTEM CT, CFT, CA at 10, 20 and 30 min, as well as reduced MCF were more likely in patients who required a MT, as compared to patients who did not. Other parameters used were EXTEM CA5 ≤ 35 mm and FIBTEM-MCF ≤ 7 mm that were also associated with the need for MT.

In transfusion guidance, FIBTEM MCF < 10 mm and EXTEM CT > 1.5 times normal were used to guide administration of FC and PCC, respectively, with a reduction of the number of RBC units used in the FC/PCC group, compared to fresh frozen plasma (FFP) group (p < 0.001). No other study reported on ROTEM® metrics utilized to guide transfusion.

Mortality was assessed in different studies, and overall, an association between hyperfibrinolysis and mortality was demonstrated (maximum lysis of 100 %, defined using ELT as control). Multiple parameters were found to be associated with mortality, including: FIBTEM < 7 mm/<9 mm/<9.5 mm, EXTEM-MCF < 45 mm; shorter EXTEM-CT, INTEM-CT, EXTEM-CFT and INTEM-CFT; higher EXTEM-MCF, INTEM-MCF.

Two systematic reviews of ROTEM® and TEG®, the similar viscoelastic currently mostly used in United States, exist for nontrauma populations. A Cochrane review [18] included nine RCTs, mostly in cardiac surgery, that compared transfusion guided by ROTEM® and TEG® with transfusion guided by clinical judgment, SCTs, or both in severely bleeding patients. This review found that ROTEM® and TEG® reduced blood loss by a mean of 85 ml (95 % CI, 29 to 141 ml) but had no effect on mortality. Another systematic review [48] included 16 observational studies and two RCTs in patients with sepsis and concluded that ROTEM® and TEG® (compared with SCTs) may detect impaired fibrinolysis, which may help to discriminate between sepsis and systemic inflammatory response syndrome (SIRS). Aside from current moderate quality, the evolving trauma literature brings evidence that ROTEM® has the potential to diagnose ACoTS, and predict and guide transfusion faster than the SCTs due to the point of care nature of the tests. Cut-off values of various ROTEM® parameters may diagnose the different nuances of ACoTS such as the different causes for hypocoagulation (low levels of clotting factors, fibrinogen and platelets, and platelet dysfunction), and hyperfibrinolysis.

Strengths and weaknesses of this study, and future research

Major limitations of this review are related to the quality of the included studies, which were not powered with proper sample sizes for detection of differences, for example. The studies were only observational, and without appropriate control groups. No randomized trials were found in the trauma population. Studies also included different transfusion triggers and transfusion protocols, limiting direct comparisons when evaluating prediction for transfusion. Reproducible technical standards for the performance of ROTEM® were lacking in the included studies. Inconsistent reporting data precluded calculation of summary diagnostic test-performance measures and exploration of threshold effects. Different cut-off values and different parameters were used, what makes standardization and interpretation difficult. A major problem faced by diagnostic studies of ACoTS is the ambiguous nature of the gold standard, given that SCTs may not provide an adequate description of all associated abnormalities or may be inferior to ROTEM® parameters. Important treatment differences between many included studies and contemporary practice include substitution of FFP for clotting factors concentrate such as PCC, FC, and cryoprecipitate, what contributed to the clinical heterogeneity across the studies. Although this review found intense heterogeneity, clinically useful and seemingly valid conclusions were reported, and will be useful in designing future studies and future clinical practice guidelines. Our findings add to the current literature importantly, as we were able to summarize and critically appraise the evidence on the threshold values of ROTEM® parameters use in trauma and demonstrate that the accuracy of the current parameters and their cut-off values need further research to be consolidated.

The information obtained in this review may be useful in designing properly and adequately powered clinical trials to detect differences in laboratory and clinical endpoints, such as bleeding, morbidity, and mortality. Confirmation to whether a resuscitation process guided by ROTEM® parameter thresholds will result in less exposure to allogeneic blood products, as compared to resuscitation guided by SCT or with a blind formula resuscitation is still warranted. Additionally, determination of specific ROTEM® parameter thresholds as independently predictors of the need for massive transfusion and mortality, assisting the trauma team with prognostication soon after arrival to hospital, are needed.

Conclusion

In summary, this systematic review finds that, consistently across all manuscripts reviewed, abnormal EXTEM and FIBTEM clot amplitude (CA5, CA10, CA20) and MCF are capable of diagnosing ACoTS (compared to SCT tests), predict the need for massive transfusion, and predict mortality. Furthermore, the presence of lysis, diagnosed by abnormal LI30 or ML is also strongly associated with mortality. Thus, based on the current available evidence we reviewed, it could be extrapolated that clinical practice guidelines using ROTEM® parameters thresholds to guide blood component transfusion could be clinically useful. Goal-directed component transfusion approach guided by ROTEM® may reduce the exposure to allogeneic blood products and the complications derived from inappropriate resuscitation. However, due to the use of arbitrary cut-off values, lack of randomized controlled trials, cohort studies with small sample sizes, without comparable controls, and heterogeneous patient populations, no further conclusions can be drawn from the literature to date. Better designed prospective studies comparing ROTEM®-guided transfusion protocols with conventional massive transfusion protocols or transfusion guided by SCTs are warranted to determine optimal parameters and accurate thresholds.

Abbreviations

ACoTS:

Acute coagulopathy of trauma and shock

ACT:

Activated clotting time

APTEM:

Aprotinin-based extrinsically activated test

aPTT:

Activated partial thromboplastin time

ATC:

Acute trauma coagulopathy

AUC:

Area under the curve

CA10:

Clot amplitude at 10 min

CA15:

Clot amplitude at 15 min

CFT:

Clot formation time

CI:

Confidence interval

CLI:

Clot lysis index

CT:

Clotting time

ELT:

Euglobin lysis time

EXTEM:

Extrinsically-activated test

FC:

Fibrinogen concentrate

FFP:

Fresh frozen plasma

FIBTEM:

Fibrin-based extrinsically activated test

HF:

Hyperfibrinolysis

INR:

International normalized ratio

INTEM:

Intrinsically-activated test

IQR:

Interquartile range

ISS:

Injury severity score

LI30:

Lysis index at 30 min

MA:

Maximal amplitude

MCF:

Maximal clot firmness

ML:

Maximum lysis

MT:

Massive transfusion

NOS:

Newcastle-Ottawa scale

NPV:

Negative predictive value

OR:

Odds ratio

PCC:

Prothrombin complex concentrate

PLT:

Platelet concentrate

POC:

Point-of-care

PPV:

Positive predictive value

PRISMA:

Preferred reporting items for systematic reviews and meta-analyses

PT:

Prothrombin time

QUADAS:

Quality assessment of diagnostic accuracy studies

RBC:

Red blood cells

RCT:

Randomized controlled trial

RCT:

Randomized controlled trial

RISC:

Revised injury severity classification

ROC:

Receiver operating curve

ROTEM®:

Rotational thromboelastometry

r-TEG®:

Rapid thromboelastography

SBP:

Systolic blood pressure

SCT:

Standard coagulation test

SD:

Standard deviation

TAT:

Turnaround time

TBI:

Traumatic brain injury

TEG®:

Thromboelastography

TEM:

Thromboelastometry

TG:

Thrombin generation

TRISS:

Trauma injury severity score

UK:

United Kingdom

References

  1. Brohi K, Singh J, Heron M, Coats T. Acute traumatic coagulopathy. J Trauma. 2003;54(6):1127–30.

    Article  PubMed  Google Scholar 

  2. Kauvar DS, Lefering R, Wade CE. Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations. J Trauma. 2006;60(6 Suppl):S3–S11.

    Article  PubMed  Google Scholar 

  3. MacLeod JB, Lynn M, McKenney MG, Cohn SM, Murtha M. Early coagulopathy predicts mortality in trauma. J Trauma. 2003;55(1):39–44.

    Article  PubMed  Google Scholar 

  4. Maegele M, Lefering R, Yucel N, et al. Early coagulopathy in multiple injury: an analysis from the German Trauma Registry on 8724 patients. Injury. 2007;38(3):298–304.

    Article  PubMed  Google Scholar 

  5. Sauaia A, Moore FA, Moore EE, et al. Epidemiology of trauma deaths: a reassessment. J Trauma. 1995;38(2):185–93.

    Article  CAS  PubMed  Google Scholar 

  6. Armand R, Hess JR. Treating coagulopathy in trauma patients. Transfus Med Rev. 2003;17(3):223–31.

    Article  PubMed  Google Scholar 

  7. Dzik WH. Predicting hemorrhage using preoperative coagulation screening assays. Curr Hematol Rep. 2004;3(5):324–30.

    PubMed  Google Scholar 

  8. Frankel HL, Rozycki GS, Ochsner MG, et al. Minimizing admission laboratory testing in trauma patients: use of a microanalyzer. J Trauma. 1994;37(5):728–36.

    Article  CAS  PubMed  Google Scholar 

  9. Rossaint R, Bouillon B, Cerny V, et al. Management of bleeding following major trauma: an updated European guideline. Crit Care. 2010;14(2):R52.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Duchesne JC, Hunt JP, Wahl G, et al. Review of current blood transfusions strategies in a mature level I trauma center: were we wrong for the last 60 years? J Trauma. 2008;65(2):272–6.

    Article  PubMed  Google Scholar 

  11. Spahn DR, Rossaint R. Coagulopathy and blood component transfusion in trauma. Br J Anaesth. 2005;95(2):130–9.

    Article  CAS  PubMed  Google Scholar 

  12. Dzik WH, Blajchman MA, Fergusson D, et al. Clinical review: Canadian National Advisory Committee on Blood and Blood Products–Massive transfusion consensus conference 2011: report of the panel. Crit Care. 2011;15(6):242.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Spahn DR, Bouillon B, Cerny V, et al. Management of bleeding and coagulopathy following major trauma: an updated European guideline. Crit Care. 2013;17(2):R76.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Gorlinger K, Dirkmann D, Hanke AA, et al. First-line therapy with coagulation factor concentrates combined with point-of-care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: a retrospective, single-center cohort study. Anesthesiology. 2011;115(6):1179–91.

    PubMed  Google Scholar 

  15. Gorlinger K, Fries D, Dirkmann D, Weber CF, Hanke AA, Schochl H. Reduction of fresh frozen plasma requirements by perioperative point-of-care coagulation management with early calculated goal-directed therapy. Transfus Med Hemother. 2012;39(2):104–13.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Tanaka KA, Bolliger D, Vadlamudi R, Nimmo A. Rotational thromboelastometry (ROTEM)-based coagulation management in cardiac surgery and major trauma. J Cardiothorac Vasc Anesth. 2012;26(6):1083–93.

    Article  PubMed  Google Scholar 

  17. Gorlinger K. Coagulation management during liver transplantation. Hamostaseologie. 2006;26(3 Suppl 1):S64–76.

    CAS  PubMed  Google Scholar 

  18. Afshari A, Wikkelso A, Brok J, Moller AM, Wetterslev J. Thrombelastography (TEG) or thromboelastometry (ROTEM) to monitor haemotherapy versus usual care in patients with massive transfusion. Cochrane Database Syst Rev. 2011;3:CD007871.

    PubMed  Google Scholar 

  19. Luddington RJ. Thrombelastography/thromboelastometry. Clin Lab Haematol. 2005;27(2):81–90.

    Article  CAS  PubMed  Google Scholar 

  20. Johansson PI, Stissing T, Bochsen L, Ostrowski SR. Thrombelastography and tromboelastometry in assessing coagulopathy in trauma. Scand J Trauma Resusc Emerg Med. 2009;17:45.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Kang YG, Martin DJ, Marquez J, et al. Intraoperative changes in blood coagulation and thrombelastographic monitoring in liver transplantation. Anesth Analg. 1985;64(9):888–96.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  22. Spalding GJ, Hartrumpf M, Sierig T, Oesberg N, Kirschke CG, Albes JM. Cost reduction of perioperative coagulation management in cardiac surgery: value of “bedside” thrombelastography (ROTEM). Eur J Cardiothorac Surg. 2007;31(6):1052–7.

    Article  PubMed  Google Scholar 

  23. Trzebicki J, Flakiewicz E, Kosieradzki M, et al. The use of thromboelastometry in the assessment of hemostasis during orthotopic liver transplantation reduces the demand for blood products. Ann Transplant. 2010;15(3):19–24.

    PubMed  Google Scholar 

  24. Brenni M, Worn M, Bruesch M, Spahn DR, Ganter MT. Successful rotational thromboelastometry-guided treatment of traumatic haemorrhage, hyperfibrinolysis and coagulopathy. Acta Anaesthesiol Scand. 2010;54(1):111–7.

    Article  CAS  PubMed  Google Scholar 

  25. Doran CM, Woolley T, Midwinter MJ. Feasibility of using rotational thromboelastometry to assess coagulation status of combat casualties in a deployed setting. J Trauma. 2010;69 Suppl 1:S40–8.

    Article  PubMed  Google Scholar 

  26. Schochl H, Frietsch T, Pavelka M, Jambor C. Hyperfibrinolysis after major trauma: differential diagnosis of lysis patterns and prognostic value of thrombelastometry. J Trauma. 2009;67(1):125–31.

    Article  PubMed  Google Scholar 

  27. Schochl H, Nienaber U, Hofer G, et al. Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate. Crit Care. 2010;14(2):R55.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Schochl H, Cotton B, Inaba K, et al. FIBTEM provides early prediction of massive transfusion in trauma. Crit Care. 2011;15(6):R265.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Schochl H, Nienaber U, Maegele M, et al. Transfusion in trauma: thromboelastometry-guided coagulation factor concentrate-based therapy versus standard fresh frozen plasma-based therapy. Crit Care. 2011;15(2):R83.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Woolley T, Midwinter M, Spencer P, Watts S, Doran C, Kirkman E. Utility of interim ROTEM((R)) values of clot strength, A5 and A10, in predicting final assessment of coagulation status in severely injured battle patients. Injury. 2013;44(5):593–9.

    Article  CAS  PubMed  Google Scholar 

  31. Liberati A, Altman DG, Tetzlaff J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 2009;62(10):e1–e34.

    Article  PubMed  Google Scholar 

  32. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg. 2010;8(5):336–41.

    Article  PubMed  Google Scholar 

  33. Cohen J. Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull. 1968;70(4):213–20.

    Article  CAS  PubMed  Google Scholar 

  34. http://www.ohri.ca/programs/clinical_epidemiology/oxford.asp. 2016. Accessed 28 Sept 2016. Ref Type: Online Source.

  35. Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529–36.

    Article  PubMed  Google Scholar 

  36. Rugeri L, Levrat A, David JS, et al. Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography. J Thromb Haemost. 2007;5(2):289–95.

    Article  CAS  PubMed  Google Scholar 

  37. Levrat A, Gros A, Rugeri L, et al. Evaluation of rotation thrombelastography for the diagnosis of hyperfibrinolysis in trauma patients. Br J Anaesth. 2008;100(6):792–7.

    Article  CAS  PubMed  Google Scholar 

  38. Leemann H, Lustenberger T, Talving P, et al. The role of rotation thromboelastometry in early prediction of massive transfusion. J Trauma. 2010;69(6):1403–8.

    Article  PubMed  Google Scholar 

  39. Schochl H, Solomon C, Traintinger S, et al. Thromboelastometric (ROTEM) findings in patients suffering from isolated severe traumatic brain injury. J Neurotrauma. 2011;28(10):2033–41.

    Article  PubMed  Google Scholar 

  40. Tauber H, Innerhofer P, Breitkopf R, et al. Prevalence and impact of abnormal ROTEM(R) assays in severe blunt trauma: results of the ‘Diagnosis and Treatment of Trauma-Induced Coagulopathy (DIA-TRE-TIC) study’. Br J Anaesth. 2011;107(3):378–87.

    Article  CAS  PubMed  Google Scholar 

  41. Davenport R, Manson J, De’Ath H, et al. Functional definition and characterization of acute traumatic coagulopathy. Crit Care Med. 2011;39(12):2652–8.

    Article  PubMed  PubMed Central  Google Scholar 

  42. Rourke C, Curry N, Khan S, et al. Fibrinogen levels during trauma hemorrhage, response to replacement therapy, and association with patient outcomes. J Thromb Haemost. 2012;10(7):1342–51.

    Article  CAS  PubMed  Google Scholar 

  43. Hagemo JS, Christiaans SC, Stanworth SJ, et al. Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study. Crit Care. 2015;19:97.

    Article  PubMed  PubMed Central  Google Scholar 

  44. Gorlinger K KRNASB. Recommendations for using the ROTEM1 in the management of non-cardiac surgery and trauma: recommendations from the ROTEM1 Expert Meeting Working* Group, Munich, 2007 version 2 May 2008. 2016

  45. Lang T, Bauters A, Braun SL, et al. Multi-centre investigation on reference ranges for ROTEM thromboelastometry. Blood Coagul Fibrinolysis. 2005;16(4):301–10.

    Article  PubMed  Google Scholar 

  46. Boyd CR, Tolson MA, Copes WS. Evaluating trauma care: the TRISS method. Trauma Score and the Injury Severity Score. J Trauma. 1987;27(4):370–8.

    Article  CAS  PubMed  Google Scholar 

  47. Offner PJ, Jurkovich GJ, Gurney J, Rivara FP. Revision of TRISS for intubated patients. J Trauma. 1992;32(1):32–5.

    Article  CAS  PubMed  Google Scholar 

  48. Muller MC, Meijers JC, Vroom MB, Juffermans NP. Utility of thromboelastography and/or thromboelastometry in adults with sepsis: a systematic review. Crit Care. 2014;18(1):R30.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We thank Ms. Ekaterina Petkova for her assistance with the literature search of this study.

Funding

This study received funding from MITACs accelerate doctoral award.

Availability of data and supporting materials

Not applicable.

Authors’ contributions

PVV, LTD participated in the study design, data collection, data analysis, manuscript preparation and revision of the manuscript. JC, SR, BN participated in the study design, manuscript preparation and revision. All authors approved the final manuscript.

Authors’ information

No relevant information to be disclosed.

Competing interests

Dr. Rizoli – Member of a Scientific Advisory Board to CSL Behring.

Dr. Jeannie Callum – Funding from TEM International for research on the use of ROTEM® in cardiac surgery.

Dr. Bartolomeu Nascimento – None.

Precilla V Veigas – None.

Luis Teodoro Da Luz – None.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Not applicable.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Luis Teodoro da Luz.

Additional file

Additional file 1:

A systematic review on the rotational thrombelastometry (ROTEM®). (DOCX 25 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Veigas, P.V., Callum, J., Rizoli, S. et al. A systematic review on the rotational thrombelastometry (ROTEM®) values for the diagnosis of coagulopathy, prediction and guidance of blood transfusion and prediction of mortality in trauma patients. Scand J Trauma Resusc Emerg Med 24, 114 (2016). https://doi.org/10.1186/s13049-016-0308-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13049-016-0308-2

Keywords