Original Article
Fast, Systematic, and Continuous Delirium Assessment in Hospitalized Patients: The Nursing Delirium Screening Scale

https://doi.org/10.1016/j.jpainsymman.2004.07.009Get rights and content
Under an Elsevier user license
open archive

Abstract

Because no rigorously validated, simple yet accurate continuous delirium assessment instrument exists, we developed the Nursing Delirium Screening Scale (Nu-DESC). The Nu-DESC is an observational five-item scale that can be completed quickly. To test the validity of the Nu-DESC, 146 consecutive hospitalized patients from a prospective cohort study were continuously assessed for delirium symptoms by bedside nurses using the Nu-DESC. Psychometric properties of Nu-DESC screening were established using 59 blinded Confusion Assessment Method (CAM) ratings made by research nurses and psychiatrists. DSM-IV criteria and the Memorial Delirium Assessment Scale (MDAS) were rated along with CAM assessments. Analysis of these data showed that the Nu-DESC is psychometrically valid and has a sensitivity and specificity of 85.7% and 86.8%, respectively. These values are comparable to those of the MDAS, a longer instrument. Nu-DESC and DSM-IV sensitivities were similar. The Nu-DESC appears to be well-suited for widespread clinical use in busy oncology inpatient settings and shows promise as a research instrument.

Key Words

Delirium
screening
monitoring
rating scales
cancer