Skip to main content
Log in

Evaluation of a fall detector based on accelerometers: A pilot study

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

As falls and fall-related injuries remain a major challenge in the public health domain, reliable and immediate detection of falls is important so that adequate medical support can be delivered. Available home alarm systems are placed on the hip, but have several shortcomings. A fall detector based on accelerometers and placed at head level was developed, as well as an algorithm able to distinguish between activities of daily living and simulated falls. Accelerometers were integrated into a hearing-aid housing, investigation into the acceleration patterns of the head of a young volunteer during intentional falls. The specificity was assessed by investigation into activities of daily living of the same volunteer. In addition, a healthy elderly woman (83 years) wore the sensor during the day. Three trigger thresholds were identified so that a fall could be recognised: the sum-vector of acceleration in the xy-plane higher than 2 g; the sumvector of velocity of all spatial components right before the impact higher than 0.7ms−1; and the sum-vector of acceleration of all spatial components higher than 6g. The algorithm was able to discriminate activities of daily living from intentional falls. Thus high sensitivity and specificity of the algorithm could be demonstrated that was better than in other fall detectors worn at the hip or wrist at the same stage of development.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Becker, C., Kron, M., Lindemann, U., Sturm, E., Eichner, B., Walter-Jung, B., andNikolaus, T. (2003): ‘Effectiveness of a multifaceted intervention on falls in nursing home residents’,J. Am. Geriatr. Soc. 51, pp. 306–313

    Article  Google Scholar 

  • Brownsell, S., andHawley, M. S. (2004): ‘Automatic fall detectors and the fear of falling’,J. Telemed. Telecare.,10, pp. 262–266

    Article  Google Scholar 

  • Cummings, S. R., Nevitt, M. C., andKidd, S. (1988): ‘Forgetting falls. The limited accuracy of recall of falls in the elderly’,J. Am. Geriatr. Soc.,36, pp. 613–616

    Google Scholar 

  • Degen, T., Jaeckel, H., Rufer, M., andWyss, S. (2003): ‘SPEEDY: A fall detector in a wrist watch’,Proc. Seventh IEEE Int. Symp. on Wearable Computers (ISWC'03), pp. 184–187

  • Doughty, K., Lewis, R., andMcIntosh, A. (2000): ‘The design of a practical and reliable fall detector for community and institutional telecare’,J. Telemed. Telecare.,6, pp. 50–54

    Article  Google Scholar 

  • Kanten, D. N., Mulrow, C. D., Gerety, M. B., Lichtenstein, M. J., Aguilar, C., andCornell, J. C. (1993): ‘Falls: an examination of three reporting methods in nursing homes’,J. Am. Geriatr. Soc.,41, pp. 662–666

    Google Scholar 

  • King, M. B., andTinetti, M. E., (1995): ‘Falls in communitydwelling older persons’,J. Am. Geriatr. Soc.,43, pp. 1146–1154

    Google Scholar 

  • Skelton, D., andTodd, C. (2004): ‘What are the main risk factors for falls amongst older people and what are the most effective interventions to prevent these falls? How should interventions to prevent falls be implemented?’, WHO Regional Office for Europe, Copenhagen, Denmark

    Google Scholar 

  • Tinetti, M. E., Doucette, J. T., andClaus, E. B. (1995): ‘The contribution of predisposing and situational risk factors to serious fall injuries’,J. Am. Geriatr. Soc.,43, pp. 1207–1213

    Google Scholar 

  • Tinetti, M. E., andWilliams, C. S. (1997): ‘Falls, injuries due to falls, and the risk of admission to a nursing home’,N. Engl. J. Med. 337, pp. 1279–1284

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to U. Lindemann.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lindemann, U., Hock, A., Stuber, M. et al. Evaluation of a fall detector based on accelerometers: A pilot study. Med. Biol. Eng. Comput. 43, 548–551 (2005). https://doi.org/10.1007/BF02351026

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02351026

Keywords

Navigation